Nitrogen Sample Concentrator CON12-NI
Concentrator refers to the amount of a substance in a defined space. Concentration is especially used for concentrating or preparing sample in batches in laboratory.
Used in Drug screening, hormone analysis, liquid phase
Also known as Laboratory Concentrator
- Synchronously working with heating by dry bath in the bottom and nitrogen blowing on the surface accelerates liquid evaporation and sample concentration.
- The length of a standard gas needle is 150mm.
- The height of the air chamber plate can be adjusted. The unique characteristics: Sample surface in the tube can be observed while concentrating.
- Gas needle is controlled independently. Separately blow of each needle and flow regulating of each needle are available to avoid gas waste.
Features
- Synchronously working with heating by dry bath in the bottom and nitrogen blowing on the surface accelerates liquid evaporation and sample concentration.
- The length of a standard gas needle is 150mm.
- The height of the air chamber plate can be adjusted. The unique characteristics: Sample surface in the tube can be observed while concentrating.
- Gas needle is controlled independently. Separately blow of each needle and flow regulating of each needle are available to avoid gas waste.
- The entire equipment can be put into ventilation cabinet when the concentration sample in toxic solvents.
- Built in overheat protection, automatic fault detection and fault beep alarm devices.
- LED displays immediate temperature and diminishing time. Operation is simple and convenient.
- Standard configured air cavity and adjustable bracket.
Specifications
Temp. Control Range | R.T.+5°C~150°C |
Temp. Setting Range | 5°C~150°C |
Heating Speed | ≤30min(40°Cto150°C) |
Temp. Accuracy (100°C) | 0.1°C |
Time Range | 1min~99h59min |
Needle Plate Max. Lift Stroke | 285 mm |
Temp. Stability@40~100°C | ±0.5°C |
Temp. Stability@100~150°C | ±1°C |
Block Temp. Uniformity@100°C | ±0.5°C |
Block Temp. Uniformity@150°C | ±1°C |
Gas-In Joint Outer Dimension | Φ7 mm |
Nitrogen Pressure | ≤0.1 Mpa |
Nitrogen Flow Rate | 0~10L/min |
Needle Length | 150 mm |
Sample Capacity | 1 Standard Visible Block |
Voltage | AC 220V/AC 110V, 50/60 Hz |
Power | 400 W |
Fuse Protector | 260x220x525 mm |
Dimension(LxWxH) | W.220xD.260xH.525 mm |
Net Weight | 5.8 kg |
Optional Accessories
Accessory Code | Name | Description | Capacity |
LS52206 | Swing-out Rotor – Adapter | Blood collection tube | 28x8/10 ml |
LS52219 | Swing-out Rotor – Adapter | Blood collection tube | 40x2-7 ml |
LS52232 | Swing-out Bucket Rotor | Falcon conical bottle | 4x175/225 ml |
LS52245 | Swing-out Bucket Rotor | 4x250 ml Corning conical bottle or 4x200 ml Nunc™ bottle or 4x175 ml Nalgene™ conical bottle | |
LS52258 | Swing-out Bucket Rotor | Blood collection tube | 28x2-7 ml |
LS52271 | Swing-out Bucket Rotor | Blood collection tube | 36x8/10 ml |
LS52284 | Swing-out Bucket Rotor | Blood collection tube | 48x2-7 ml |